Faro

ScanArms with RevEng – PORTABLE CMM

FARO® Quantum Max ScanArms with RevEngTM Software

The global standard in non-contact measurement arm technology, which combine the measurement capabilities of a Quantum Max FaroArm® portable coordinate measuring machine (CMM) with the non-contact functionality of a laser line probe.

The Quantum Max also offers three LLPs that optimize accuracy, speed or a blend of both, depending on project need. Whichever LLP you choose, 3D ScanArms capture precise measurements in nearly any environment, from the factory floor to the field.

 

 

 

Sometimes a part or tool is so complex, you can’t use contact probes to capture all of its measurements.

But lasers do the job with exceptional speed and accuracy. In these cases, leading manufacturers rely on FARO Quantum Max ScanArms, which combine the measurement capabilities of a Quantum Max FaroArm® portable coordinate measuring machine (CMM) with the non-contact functionality of a laser line probe.

The Quantum Max also offers three LLPs that optimize accuracy, speed or a blend of both, depending on project need. Whichever LLP you choose, 3D ScanArms capture precise measurements in nearly any environment, from the factory floor to the field.

 

ScanArm Features


  • Family of Laser Line Probes (LLPs) : Achieve high-speed point cloud capture, high accuracy or a blend of both with three LLPs, each hot swappable and purpose built.
  • Multiple Working Volumes : Meet the needs of any application with working volumes of 2.0m, 2.5m, 3m, 3.5m and 4m.
  • Continuous Light Rectification (CLR) Technology : Scan dark, reflective or translucent surfaces.
  • Smart Probe Capability : Quickly and easily change probes without recalibration.
  • Internal Counterbalancing : Operate with a single hand and without fatigue.
  • Ergonomic Design : Transport, set up and operate ScanArms with ease and comfort.
  • Exclusive 8-axis Integration : Quickly measure all sides of a part without repositioning.
  • Compliance : Meet rigorous ISO 10360-12 accuracy standards.
  • Universal Quick Mount : Set up a ScanArm wherever it’s needed.
  • Temperature and Overload Sensors : Ensure continuous, optimum performance.
  • Powerful Software Solutions : Easily integrate ScanArms and software.
  • Extended Battery Use Option : Operate without cables.
  • High-speed Wireless Operation : Connect with Bluetooth or Wi-Fi.
  • Rugged Design : Use ScanArms even in the most challenging measurement environments.

 

ScanArms By Performance Level

QUANTUM MAX SCANARMS – Maximum Performance
QuantumS is the flagship measurement arm, delivering premium accuracy and performance. QuantumM provides the global standard in portable metrology and boasts an ideal price/performance ratio, well suited for factory inspection tasks. QuantumE offers excellent performance at a competitive price and ensures high-quality production.
FAROBLU XR – Maximum Resolution & Accuracy
This Laser Line Probe (LLP) is ideal for high-precision tasks with tight tolerances to capture data at highest accuracy and best resolution possible. Users can scan small intricate parts and fine details with 1.5 times the accuracy, improving production quality with better and more reliable data.

FAROBLU XP – Maximum Productivity

This Laser Line Probe (LLP) offers the ability to scan anything with a balanced blend of accuracy, speed and coverage—increasing profitability and throughput with performance suitable for any application.

FAROBLU XS – Maximum Speed

This Laser Line Probe (LLP) is best for large parts or expansive surface areas when data collection speed is top priority. The extra‑wide laser stripe delivers double the coverage in a single pass, allowing users to collect data up to 2.6x faster than the xR and 1.6X faster than the xP. Fewer passes to collect data means faster results and higher productivity.

8-Axis Scanning Platform – Faster Scanning with Any Quantum V2 ScanArm

An industry first, the integrated 8-axis rotary scanning platform decreases scan time by up to 40%, while maintaining accuracy. The platform is available with all ScanArm models; select the 8-Axis QuantumS ScanArm, 8-Axis QuantumM ScanArm or the 8-Axis QuantumE ScanArm.

 

FARO® RevEngTM Software


  • Time Saving : Mesh Optimization Tools & 3D Shapes Extraction
  • Flexibility : Nurbs Sketch Tool (Auto-surfacing Or Manual)
  • Time saver and quality increaser : Mesh Generation Tools
  • Streamline and Fast Processes : Scan-to-cad Platform
  • Versatility : Import And Export In Standards Formats

 

3D Metrology Applications


 

Improved Quality Control and Inspection

Verify dimensional accuracy and identify deviations from nominal CAD data during first-article and in-process inspection, as well as inspection of incoming parts.

Production, Fabrication and Assembly 

Keep production machinery calibrated and aligned, and verify dimensional accuracy of tooling and parts.

 

Faster, More Accurate Product Design and Engineering

Expedite reverse-engineering and rapid prototyping for shorter time to market.

 

Business Value of ScanArms


  • Scan More, Scan Better, Scan Faster : Increase your productivity without the need to compromise between speed and accuracy.
  • Ensure Consistency and Repeatability : Every operator gets the same results every time.
  • Optimize Operations : Precision measurement reduces scrap, rework and inspection bottlenecks.
  • Capture Production Data : Accurate data allows for reporting and trend analysis.
  • Improve Quality : Complex 3D inspections and automatic reports help users pinpoint defects.
  • Capture Details : The FARO laser ScanArm captures extreme measurement detail on complicated parts and objects.
  • Enhance Yield : Faster troubleshooting and root-cause analysis help increase overall yield.
  • Increase Throughput : Higher production rates and reduced downtime for verification mean greater throughput.
  • Accelerate Revenue Generation : You’ll bring products to market faster and reduce rework and downtime.
  • Keep Customers and End Users Happy : Delivering higher-quality products that can be used with confidence makes everyone happy and keeps customers loyal.
  • Make Informed Decisions : With the information at your team’s fingertips, they’ll be equipped to make smarter decisions faster and stay ahead of any problems.

ScanArm System Accuracy – Non-Contact Measurement** (FaroArm with LLP)

 

QuantumS Max
FAROBlu Max xR xP xS
2.0m (6.6ft) 0.03mm
0.0012in
0.038mm
0.0015in
0.046mm
0.0018in
2.5m (8.2ft) 0.034mm
0.0013in
0.042mm
0.0017in
0.05mm
0.002in
3.0m (9.8ft) 0.04mm
0.0016in
0.048mm
0.0019in
0.055mm
0.0022in
3.5m (11.5ft) 0.054mm
0.0021in
0.061mm
0.0024in
0.068mm
0.0027in
4.0m (13.1ft) 0.068mm
0.0027in
0.074mm
0.0029in
0.08mm
0.0031in

 

QuantumM Max
FAROBlu Max xR xP xS
2.0m (6.6ft) 0.035mm
0.0014in
0.041mm
0.0016in
0.052mm
0.002in
2.5m (8.2ft) 0.039mm
0.0015in
0.046mm
0.0018in
0.056mm
0.0022in
3.0m (9.8ft) 0.046mm
0.0018in
0.053mm
0.0021in
0.062mm
0.0024in
3.5m (11.5ft) 0.062mm
0.0024in
0.067mm
0.0026in
0.076mm
0.003in
4.0m (13.1ft) 0.078mm
0.0031in
0.081mm
0.0032in
0.09mm
0.0035in

 

QuantumE Max
FAROBlu Max xR xP xS
2.0m (6.6ft) 0.042mm
0.0017in
0.053mm
0.0021in
0.06mm
0.0024in
2.5m (8.2ft) 0.048mm
0.0019in
0.059mm
0.0023in
0.065mm
0.0026in
3.0m (9.8ft) 0.056mm
0.0022in
0.067mm
0.0026in
0.077mm
0.003in
3.5m (11.5ft) 0.076mm
0.003in
0.085mm
0.0033in
0.095mm
0.0037in
4.0m (13.1ft) 0.095mm
0.0037in
0.104mm
0.0041in
0.112mm
0.0044in

 


FaroArm Accuracy – Contact Measurement* (7-Axis)

QuantumS Max
7-Axis SPAT1 PSIZE2 PFORM3 LDIA4 EUNI5
2.0m (6.6ft) 0.018mm
0.0007in
0.01mm
0.0004in
0.02mm
0.0008in
0.04mm
0.0016in
0.025mm
0.001in
2.5m (8.2ft) 0.02mm
0.0008in
0.011mm
0.0004in
0.022mm
0.0009in
0.044mm
0.0017in
0.028mm
0.0011in
3.0m (9.8ft) 0.032mm
0.0013in
0.016mm
0.0006in
0.032mm
0.0013in
0.074mm
0.0029in
0.05mm
0.002in
3.5m (11.5ft) 0.045mm
0.0018in
0.02mm
0.0008in
0.039mm
0.0015in
0.09mm
0.0035in
0.062mm
0.0024in
4.0m (13.1ft) 0.055mm
0.0022in
0.026mm
0.001in
0.044mm
0.0017in
0.108mm
0.0043in
0.076mm
0.003in

 

QuantumM Max
7-Axis SPAT1 PSIZE2 PFORM3 LDIA4 EUNI5
2.0m (6.6ft) 0.023mm
0.0009in
0.012mm
0.0005in
0.024mm
0.0009in
0.045mm
0.0018in
0.029mm
0.0011in
2.5m (8.2ft) 0.027mm
0.0011in
0.013mm
0.0005in
0.026mm
0.001in
0.049mm
0.0019in
0.032mm
0.0013in
3.0m (9.8ft) 0.042mm
0.0017in
0.02mm
0.0008in
0.036mm
0.0014in
0.08mm
0.0031in
0.054mm
0.0021in
3.5m (11.5ft) 0.055mm
0.0022in
0.024mm
0.0009in
0.043mm
0.0017in
0.096mm
0.0038in
0.066mm
0.0026in
4.0m (13.1ft) 0.065mm
0.0026in
0.029mm
0.0011in
0.048mm
0.0019in
0.118mm
0.0046in
0.082mm
0.0032in

 

QuantumE Max
7-Axis SPAT1 PSIZE2 PFORM3 LDIA4 EUNI5
2.0m (6.6ft) 0.028mm
0.0011in
0.016mm
0.0006in
0.035mm
0.0014in
0.05mm
0.002in
0.04mm
0.0016in
2.5m (8.2ft) 0.035mm
0.0014in
0.02mm
0.0008in
0.04mm
0.0016in
0.055mm
0.0022in
0.046mm
0.0018in
3.0m (9.8ft) 0.055mm
0.0022in
0.028mm
0.0011in
0.051mm
0.002in
0.088mm
0.0035in
0.066mm
0.0026in
3.5m (11.5ft) 0.075mm
0.003in
0.036mm
0.0014in
0.062mm
0.0024in
0.11mm
0.0043in
0.082mm
0.0032in
4.0m (13.1ft) 0.095mm
0.0037in
0.044mm
0.0017in
0.075mm
0.003in
0.136mm
0.0054in
0.1mm
0.0039in

 


FaroArm Accuracy – Contact Measurement* (6-Axis)

QuantumS Max
6-Axis SPAT1 PSIZE2 PFORM3 LDIA4 EUNI5
2.0m (6.6ft) 0.016mm
0.0006in
0.008mm
0.0003in
0.017mm
0.0007in
0.03mm
0.0012in
0.024mm
0.0009in
2.5m (8.2ft) 0.018mm
0.0007in
0.009mm
0.0004in
0.018mm
0.0007in
0.032mm
0.0013in
0.026mm
0.001in
3.0m (9.8ft) 0.027mm
0.0011in
0.012mm
0.0005in
0.026mm
0.001in
0.046mm
0.0018in
0.038mm
0.0015in
3.5m (11.5ft) 0.036mm
0.0014in
0.016mm
0.0006in
0.034mm
0.0013in
0.064mm
0.0025in
0.052mm
0.002in
4.0m (13.1ft) 0.045mm
0.0018in
0.02mm
0.0008in
0.038mm
0.0015in
0.078mm
0.0031in
0.063mm
0.0025in

 

QuantumM Max
6-Axis SPAT1 PSIZE2 PFORM3 LDIA4 EUNI5
2.0m (6.6ft) 0.02mm
0.0008in
0.01mm
0.0004in
0.022mm
0.0009in
0.035mm
0.0014in
0.027mm
0.0011in
2.5m (8.2ft) 0.023mm
0.0009in
0.013mm
0.0005in
0.023mm
0.0009in
0.038mm
0.0015in
0.03mm
0.0012in
3.0m (9.8ft) 0.034mm
0.0013in
0.016mm
0.0006in
0.032mm
0.0013in
0.052mm
0.002in
0.042mm
0.0017in
3.5m (11.5ft) 0.044mm
0.0017in
0.02mm
0.0008in
0.039mm
0.0015in
0.068mm
0.0027in
0.056mm
0.0022in
4.0m (13.1ft) 0.053mm
0.0021in
0.024mm
0.0009in
0.044mm
0.0017in
0.084mm
0.0033in
0.067mm
0.0026in

 

All values represent MPE (Maximum Permissible Error)

* Contact Measurement (FaroArm) : In Accordance with ISO 10360-12. With optional 8-Axis (FaroArm + 8-Axis) full system performance based on ISO10360-12 Sphere Location Diameter Error (LDIA)

** Non-Contact Measurement (ScanArm and ScanArm + 8-Axis): Based on ISO 10360-8 Annex D; defined as LDIA (Sphere Location Diameter Error) – Diameter of the spherical zone containing the centers of a sphere measure from multiple orientations. Values are absolute

1 SPAT – Single Point Articulation Test

2 EUNI – Distance Error between two points comparing measured versus nominal values

3 PSIZE – Sphere Probing Size Error comparing measured versus nominal values

4 PFORM – Sphere Probing Form Error

5 LDIA – Sphere Location Diameter Error (Diameter of the spherical zone containing the centers of a sphere measured from multiple orientations)